EZ5002 Total Hardness Analyser (TH, THCa), 1 stream, Modbus RS485

EZ5002 Total Hardness Analyser (TH, THCa), 1 stream, Modbus RS485
Termékszám: EZ5002.99001C02
HUF Ár (nettó): Elérhetőségünk

Műszaki adatok

Anyag: Hinged part: Thermoform ABS, door: plexiglass
Wall section: Galvanised steel, powder coated
Demineralised water: For rinsing / dilution
Detektálási határ: ≤ 10 mg/L
Digitális kimenetek: Modbus RS485
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garancia: 2 év
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenciák: Hardness: Some metal ions interfere by causing fading or indistinct end points or by stoichiometric consumption of EDTA. Suspended or colloidal organic matter also may interfere with the end point. Large amounts of colour and turbidity interferes. Fats, oil, proteins, surfactants and tar.
Alkalinity: Soaps, oily matter, suspended solids or precipitates may coat the glass electrode and cause a sluggish response. Allow additional time between titrant additions to let the electrode come to equilibrium or clean the electrodes occasionally.
Kalibrálás: N.A.
Kimenet : Modbus RS485

Optional:
Active 4 - 20 mA max. 500 Ohm load, 1 to 8 outputs
RS232, Modbus TCP/IP
Környezeti hőmérséklet: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Lefolyócső: Atmospheric pressure, vented, min. Ø 64 mm
Mérés módszer: Acid-base titration (alkalinity only); Calmagite EDTA titration with LED dipping probe (combined)
Méréstartomány: 100 - 1000 mg/L CaCO3

Optional:
10 - 100 mg/L CaCO3
25 - 250 mg/L CaCO3
50 - 500 mg/L CaCO3
Internal dispenser dilution (max. factor 100)
Méretek (MxSZxM): 690 mm x 465 mm x 330 mm
Minta: nyomás: By external overflow vessel
Mintaáram: 100 - 300 mL/min
Mintacellák: 20 - 30 minutes
40 minutes (+ Total Hardness Ca)
Minta hőmérséklet: 10 - 30 °C
Minta minőség: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Mintautak száma: 1 stream

Optional:
1 to 8 streams
Paraméter: Total Hardness & Calcium Hardness (THCa)
Pontosság: Better than 2% full scale range for standard test solutions
Reagent Requirements: Keep between 10 - 30 °C
Riasztás: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Súly: 25 kg
Tanúsítványok: CE compliant / UL certified
Teljesítmény: 110 - 220 VAC, 2 A, 50/60Hz
Max. power consumption: 150 VA
Other voltages available on request
Validation: Automatic; frequency freely programmable
Védettségi osztály: Analyser cabinet: IP55 / Panel PC: IP65