A doboz tartalma:
EZ7700 Total Nitrogen Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x empty 2.5L Reagent Container with Fittings (Buffer Solution), 2 x empty 5L Reagent Containers with Fittings (Oxidation B & Reductor Solution), 1 x empty 10L Reagent Container with Fittings (Oxidation A Solution) and 1 x empty 2.5L Glass Reagent Container with Fittings (Colour Solution)
Analóg kimenetek:
Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Anyag:
Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Automatikus tisztítás:
Igen
Cooling water:
Flow rate approx. 5 L/h; temperature max. 30 °C; pressure max. 0.5 bar
Demineralised water:
For rinsing
Detektálási határ:
≤ 100 µg/L
Digitális kimenetek:
Optional: Modbus (TCP/IP, RS485)
Earth connection:
Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Garancia:
24 hónap
Instrument air:
Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Interferenciák:
Antimony (III), Bismuth (III), Chloroplatinate, Gold (III), Iron (III), Lead (II), Mercury (II), Metavanadate, and Silver (I) can precipitate with Nitrate. The presence of Copper (II) may decompose the diazonium salt which results in a low result. Strong oxidising agents. NCl₃ results in a false red colour. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Kalibrálás:
Automatic, 2-point; frequency freely programmable
Környezeti hőmérséklet:
10 - 30 °C, ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Lefolyócső:
Atmospheric pressure, vented, min. Ø 32 mm
Mérés módszer:
Colorimetric measurement at 546 nm using hydrazine reduction and NEDD colour solution after persulphate digestion in alkaline medium, conform with APHA 4500-N
Méréstartomány:
0.1 - 2 mg/L TN
Méretek (MxSZxM):
690 mm x 465 mm x 330 mm
Minta: nyomás:
By external overflow vessel
Mintaáram:
100 - 300 mL/min
Mintacellák:
30 min including digestion of 10 min (standard)
Minta hőmérséklet:
10 - 30 °C
Minta minőség:
Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Mintautak száma:
1, 2, 4, or 8
Paraméter:
Total Nitrogen (TN)
Pontosság:
Better than 3% full scale range for standard test solutions
Reagent Requirements:
Keep between 10 - 30 °C
Riasztás:
1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Súly:
25 kg
Tanúsítványok:
CE compliant / UL certified
Teljesítmény:
230 VAC, 50/60 Hz
120 VAC, 50/60 Hz
Max. power consumption: 440 VA
Típus:
EZ7700
Validation:
Automatic; frequency freely programmable
Védettségi osztály:
Analyser cabinet: IP55 / Panel PC: IP65